XYPLEX-BRIDGE-MIB DEFINITIONS ::= BEGIN IMPORTS Gauge, OBJECT-TYPE, enterprises, Counter, TimeTicks FROM RFC1155-SMI DisplayString FROM SNMPv2-TC; xyplex OBJECT IDENTIFIER ::= { enterprises 33 } bridge OBJECT IDENTIFIER ::= { xyplex 5 } -- the system group brsys OBJECT IDENTIFIER ::= { bridge 1 } brsysName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory ::= { brsys 1 } brsysMacAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-only STATUS mandatory ::= { brsys 2 } brsysUpTime OBJECT-TYPE -- (duplicate of system) SYNTAX TimeTicks ACCESS read-only STATUS mandatory ::= { brsys 3 } brsysLatEnhance OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { brsys 4 } brsysLatAnnceCompTblSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { brsys 5 } brsysPcktCompTblSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { brsys 6 } brsysForwardQueueDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { brsys 7 } brsysLocalQueueDisc OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { brsys 8 } brsysVitalinkMacAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-write STATUS mandatory ::= { brsys 9 } brsysLatAnnceCompTblUseSize OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { brsys 10 } brsysLatAnnceCompTblUseHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { brsys 11 } brsysPcktCompTblUseSize OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { brsys 12 } brsysPcktCompTblUseHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { brsys 13 } -- the stp group stp OBJECT IDENTIFIER ::= { bridge 2 } stpStp OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { stp 1 } stpForwardTimer OBJECT-TYPE SYNTAX INTEGER (1..3600) -- in seconds ACCESS read-write STATUS mandatory ::= { stp 2 } stpHelloTimer OBJECT-TYPE SYNTAX INTEGER (1..3600) -- in seconds ACCESS read-write STATUS mandatory ::= { stp 3 } stpMaxAgeTimer OBJECT-TYPE SYNTAX INTEGER (1..3600) -- in seconds ACCESS read-write STATUS mandatory ::= { stp 4 } stpMulticastAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-write STATUS mandatory ::= { stp 5 } stpPriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory ::= { stp 6 } stpTopChngTimer OBJECT-TYPE SYNTAX INTEGER -- in seconds ACCESS read-only STATUS mandatory ::= { stp 7 } stpDesigRoot OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-only STATUS mandatory ::= { stp 8 } stpDesigRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stp 9 } stpDesigForwardTimer OBJECT-TYPE SYNTAX INTEGER -- in seconds ACCESS read-only STATUS mandatory ::= { stp 10 } stpDesigHelloTimer OBJECT-TYPE SYNTAX INTEGER -- in seconds ACCESS read-only STATUS mandatory ::= { stp 11 } stpDesigMaxAgeTimer OBJECT-TYPE SYNTAX INTEGER -- in seconds ACCESS read-only STATUS mandatory ::= { stp 12 } stpDesigRootLink OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stp 13 } stpDesigRootPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stp 14 } stpTopChngCount OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { stp 15 } stpTopStableTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory ::= { stp 16 } stpTopState OBJECT-TYPE SYNTAX INTEGER { stable(1), changing(2) } ACCESS read-only STATUS mandatory ::= { stp 17 } stpNumLinks OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { stp 18 } stpLinkTbl OBJECT-TYPE SYNTAX SEQUENCE OF StpLinkTblEnt ACCESS not-accessible STATUS mandatory ::= { stp 19 } stpLinkTblEnt OBJECT-TYPE SYNTAX StpLinkTblEnt ACCESS not-accessible STATUS mandatory ::= { stpLinkTbl 1 } StpLinkTblEnt ::= SEQUENCE { stpLinkID INTEGER, stpLinkMacAddress OCTET STRING, stpLinkPriority INTEGER, stpLinkPathcost INTEGER, stpLinkPathcostCur INTEGER, stpLinkPathcostWeighted INTEGER, stpLinkState INTEGER, stpLinkDesigRoot OCTET STRING, stpLinkDesigCost INTEGER, stpLinkDesigBridge OCTET STRING, stpLinkDesigLink INTEGER, stpLinkTopChngAck INTEGER } stpLinkID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 1 } stpLinkMacAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ?? ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 2 } stpLinkpriority OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory ::= { stpLinkTblEnt 3 } stpLinkPathcost OBJECT-TYPE SYNTAX INTEGER (0..65534) -- { Auto(65535) } ACCESS read-write STATUS mandatory ::= { stpLinkTblEnt 4 } stpLinkPathcostCur OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 5 } stpLinkPathcostWeighted OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { stpLinkTblEnt 6 } stpLinkState OBJECT-TYPE SYNTAX INTEGER { disabled(1), blocked(2), forwarding(3), learning(4), listening(5) } ACCESS read-write STATUS mandatory ::= { stpLinkTblEnt 7 } stpLinkDesigRoot OBJECT-TYPE SYNTAX OCTET STRING -- format ?? ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 8 } stpLinkDesigCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 9 } stpLinkDesigBridge OBJECT-TYPE SYNTAX OCTET STRING -- format ?? ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 10 } stpLinkDesigLink OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 11 } stpLinkTopChngAck OBJECT-TYPE SYNTAX INTEGER { notAcknowledged(1), acknowledged(2) } ACCESS read-only STATUS mandatory ::= { stpLinkTblEnt 12 } stpMaxForwardDelay OBJECT-TYPE SYNTAX INTEGER -- { none(0) } otherwise milliseconds ACCESS read-write STATUS mandatory ::= { stp 20 } stpMaxMultiForwardDelay OBJECT-TYPE -- multicast delay SYNTAX INTEGER --{ none(0) } otherwise milliseconds ACCESS read-write STATUS mandatory ::= { stp 21 } stpEarlyLoopDetection OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { stp 22 } stpEarlyLoopCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { stp 23 } -- the filters group fl OBJECT IDENTIFIER ::= { bridge 3 } flFiltering OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { fl 1 } flTableSize OBJECT-TYPE SYNTAX INTEGER (10..4000) ACCESS read-write STATUS mandatory ::= { fl 2 } flDiscardTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) -- in seconds ACCESS read-write STATUS mandatory ::= { fl 3 } flUseTimeout OBJECT-TYPE SYNTAX INTEGER (0..65535) -- in seconds ACCESS read-write STATUS mandatory ::= { fl 4 } flSrcNumSourceCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 5 } flSrcNumSourceHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 6 } flSrcNumSourceMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 7 } flSrcFilterTbl OBJECT-TYPE SYNTAX SEQUENCE OF FlSrcFilterTblEnt ACCESS not-accessible STATUS mandatory ::= { fl 8 } flSrcFilterTblEnt OBJECT-TYPE SYNTAX FlSrcFilterTblEnt ACCESS not-accessible STATUS mandatory ::= { flSrcFilterTbl 1 } FlSrcFilterTblEnt ::= SEQUENCE { flSrcEntID INTEGER, flSrcEntMacAddress OCTET STRING, flSrcEntForwardFlag INTEGER, flSrcEntUseCount Counter } flSrcEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { flSrcFilterTblEnt 1 } flSrcEntMacAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-write STATUS mandatory ::= { flSrcFilterTblEnt 2 } flSrcEntForwardFlag OBJECT-TYPE SYNTAX INTEGER { discard(1), forward(2) } ACCESS read-write STATUS mandatory ::= { flSrcFilterTblEnt 3 } flSrcEntUseCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { flSrcFilterTblEnt 4 } flDstInactiveNumCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 9 } flDstInactiveNumHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 10 } flDstInactiveNumMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 11 } flDstLearnedNumCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 12 } flDstLearnedNumHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 13 } flDstLearnedNumMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 14 } flDstLearnedNumErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { fl 15 } flDstStaticNumCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 16 } flDstStaticNumHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 17 } flDstStaticNumMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { fl 18 } flDstFilterTbl OBJECT-TYPE SYNTAX SEQUENCE OF FlDstFilterTblEnt ACCESS not-accessible STATUS mandatory ::= { fl 19 } flDstFilterTblEnt OBJECT-TYPE SYNTAX FlDstFilterTblEnt ACCESS not-accessible STATUS mandatory ::= { flDstFilterTbl 1 } FlDstFilterTblEnt ::= SEQUENCE { flDstEntID INTEGER, flDstEntMacAddress OCTET STRING, flDstEntLinkMap OCTET STRING, flDstEntStatus INTEGER, flDstEntTtl Gauge, flDstEntUseCount Counter } flDstEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { flDstFilterTblEnt 1 } flDstEntMacAddress OBJECT-TYPE SYNTAX OCTET STRING -- format ??? ACCESS read-write STATUS mandatory ::= { flDstFilterTblEnt 2 } flDstEntLinkMap OBJECT-TYPE SYNTAX OCTET STRING -- bit map of links to forward to ACCESS read-write STATUS mandatory ::= { flDstFilterTblEnt 3 } flDstEntStatus OBJECT-TYPE SYNTAX INTEGER { static(1), learned(2), inactive(3) } ACCESS read-write STATUS mandatory ::= { flDstFilterTblEnt 4 } flDstEntTtl OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory ::= { flDstFilterTblEnt 5 } flDstEntUseCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { flDstFilterTblEnt 6 } flLinkTbl OBJECT-TYPE SYNTAX SEQUENCE OF FlLinkTblEnt ACCESS not-accessible STATUS mandatory ::= { fl 20 } flLinkTblEnt OBJECT-TYPE SYNTAX FlLinkTblEnt ACCESS not-accessible STATUS mandatory ::= { flLinkTbl 1 } FlLinkTblEnt ::= SEQUENCE { flLinkEntID INTEGER, flLinkEntLearning INTEGER } flLinkEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { flLinkTblEnt 1 } flLinkEntLearning OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { flLinkTblEnt 2 } -- the protocols group prtcl OBJECT IDENTIFIER ::= { bridge 4 } prtclProtocol OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { prtcl 1 } prtclNumCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { prtcl 2 } prtclNumMax OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { prtcl 3 } prtclTbl OBJECT-TYPE SYNTAX SEQUENCE OF PrtclTblEnt ACCESS not-accessible STATUS mandatory ::= { prtcl 4 } prtclTblEnt OBJECT-TYPE SYNTAX PrtclTblEnt ACCESS not-accessible STATUS mandatory ::= { prtclTbl 1 } PrtclTblEnt ::= SEQUENCE { prtclEntID INTEGER, prtclEntProtocolID INTEGER, prtclEntMac INTEGER, prtclEntName DisplayString, prtclEntPriority INTEGER, prtclEntUseCount Counter } prtclEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { prtclTblEnt 1 } prtclEntProtocolID OBJECT-TYPE -- mac ID is mac is True; else N/A SYNTAX INTEGER ACCESS read-write STATUS mandatory ::= { prtclTblEnt 2 } prtclEntMac OBJECT-TYPE SYNTAX INTEGER { non-Mac(1), mac(2) } ACCESS read-write STATUS mandatory ::= { prtclTblEnt 3 } prtclEntName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..24)) ACCESS read-write STATUS mandatory ::= { prtclTblEnt 4 } prtclEntPriority OBJECT-TYPE SYNTAX INTEGER { low(1), medium(3), high(5), discard(101) } ACCESS read-write STATUS mandatory ::= { prtclTblEnt 5 } prtclEntUseCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { prtclTblEnt 6 } prtclDefaultPriority OBJECT-TYPE SYNTAX INTEGER { low(1), medium(3), high(5), discard(101) } ACCESS read-write STATUS mandatory ::= { prtcl 5 } prtclDefaultUseCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { prtcl 6 } -- the links group lks OBJECT IDENTIFIER ::= { bridge 5 } lksNum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lks 1 } lksTbl OBJECT-TYPE SYNTAX SEQUENCE OF LksTblEnt ACCESS not-accessible STATUS mandatory ::= { lks 2 } lksTblEnt OBJECT-TYPE SYNTAX LksTblEnt ACCESS not-accessible STATUS mandatory ::= { lksTbl 1 } LksTblEnt ::= SEQUENCE { lksEntID INTEGER, lksEntStateConfig INTEGER, lksEntStateActive INTEGER, lksEntType INTEGER, lksEntTypeSpecific OBJECT IDENTIFIER, lksEntName DisplayString, lksEntUtilizationCur Gauge, lksEntUtilizationHigh Gauge, lksEntUtilizationAvg Gauge, lksEntForwardingCur Gauge, lksEntForwardingHigh Gauge, lksEntForwardingAvg Gauge, lksEntFilteringCur Gauge, lksEntFilteringHigh Gauge, lksEntFilteringAvg Gauge, lksEntOutputQCur Gauge, lksEntOutputQHigh Gauge, lksEntOutputQTotal Gauge, lksEntTransmitLinkSpeed Gauge, lksEntReceiveLinkSpeed Gauge, lksEntTraffic OBJECT IDENTIFIER, lksEntDiscards OBJECT IDENTIFIER } lksEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { lksTblEnt 1 } -- standby is not supported in the first pass lksEntStateConfig OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2), standby(3) } ACCESS read-write STATUS mandatory ::= { lksTblEnt 2 } lksEntStateActive OBJECT-TYPE SYNTAX INTEGER { initWaitDSR(129), initWait(130), down1(132),down(135), purging1(133), purging(136), running1(131), running(134), loop(136), testSend(138), testReceive(139), testLoop(140) } ACCESS read-only STATUS mandatory ::= { lksTblEnt 3 } lksEntType OBJECT-TYPE SYNTAX INTEGER { unknown(1), wan(3), lan(4) } -- Undefined is UNKNOWN ACCESS read-only STATUS mandatory ::= { lksTblEnt 4 } lksEntTypeSpecific OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory ::= { lksTblEnt 5 } lksEntName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) ACCESS read-write STATUS mandatory ::= { lksTblEnt 6 } lksEntUtilizationCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 7 } lksEntUtilizationHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 8 } lksEntUtilizationAvg OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 9 } lksEntForwardingCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 10 } lksEntForwardingHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 11 } lksEntForwardingAvg OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 12 } lksEntFilteringCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 13 } lksEntFilteringHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 14 } lksEntFilteringAvg OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 15 } lksEntOutputQCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 16 } lksEntOutputQHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 17 } lksEntOutputQTotal OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 18 } lksEntTransmitLinkSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 19 } lksEntReceiveLinkSpeed OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { lksTblEnt 20 } lksEntTraffic OBJECT IDENTIFIER ::= { lksTblEnt 21 } lksEntTrafficPacketsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 1 } lksEntTrafficPacketsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 2 } lksEntTrafficMulticastsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 3 } lksEntTrafficMulticastsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 4 } lksEntTrafficUnicastsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 5 } lksEntTrafficUnicastsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 6 } lksEntTrafficStpIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 7 } lksEntTrafficStpOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 8 } lksEntTrafficBytesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 9 } lksEntTrafficBytesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntTraffic 10 } lksEntDiscards OBJECT IDENTIFIER ::= { lksTblEnt 22 } lksEntDiscardCrcError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 1 } lksEntDiscardFiltering OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 2 } lksEntDiscardnoBuffers OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 3 } lksEntDiscardPriority OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 4 } lksEntDiscardLatGroupAnnce OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 5 } lksEntDiscardLostBuffers OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 6 } lksEntDiscardOutputQueueFull OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 7 } lksEntDiscardDelayExceeded OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lksEntDiscards 8 } -- the wan group wan OBJECT IDENTIFIER ::= { bridge 6 } wanNullClock OBJECT-TYPE SYNTAX INTEGER -- 0, 8.333k, 66.667k, 250k, 2M ACCESS read-write STATUS mandatory ::= { wan 1 } wanNum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wan 2 } wanTbl OBJECT-TYPE SYNTAX SEQUENCE OF WanTblEnt ACCESS not-accessible STATUS mandatory ::= { wan 3 } wanTblEnt OBJECT-TYPE SYNTAX WanTblEnt ACCESS not-accessible STATUS mandatory ::= { wanTbl 1 } WanTblEnt ::= SEQUENCE { wanEntID INTEGER, wanEntCompression INTEGER, wanEntDsrTimeout INTEGER, -- next field is not supported first pass wanEntLocalPhone DisplayString, -- next field is not supported first pass wanEntDialPhoneNumMax INTEGER, -- next field is not supported first pass -- wanEntDialPhoneTbl -- SEQUENCE OF LksEntDialPhoneEnt, wanEntGroups OCTET STRING, -- next field is not supported first pass wanEntModemType INTEGER, wanEntNullClock -- depricated field INTEGER, wanEntPathcostWeighted INTEGER, wanEntErrorRateCur Gauge, wanEntErrorRateHigh Gauge, wanEntErrorRateAvg Gauge, wanEntLinkDownCur Gauge, wanEntLinkDownHigh Gauge, wanEntLinkDownTotal Counter, wanEntLinkDownCount Counter, wanEntCableType INTEGER, wanEntCtsCur INTEGER, wanEntRtsCur INTEGER, wanEntDcdCur INTEGER, wanEntDsrCur INTEGER, wanEntDtrCur INTEGER, wanEntRingCur INTEGER, wanEntCtsChanges Counter, wanEntRtsChanges Counter, wanEntDcdChanges Counter, wanEntDsrChanges Counter, wanEntDtrChanges Counter, wanEntRingChanges Counter, wanEntCompNum Counter, wanEntCompressionTbl WanEntCompEnt, wanEntCompressionStatus INTEGER } wanEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { wanTblEnt 1 } wanEntCompression OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), auto(256) } ACCESS read-write STATUS mandatory ::= { wanTblEnt 2 } wanEntDsrTimeout OBJECT-TYPE SYNTAX INTEGER (0..1000) ACCESS read-write STATUS mandatory ::= { wanTblEnt 3 } -- next field is not supported first pass wanEntLocalPhone OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) -- a dialable string passed to modem ACCESS read-write STATUS mandatory ::= { wanTblEnt 4 } -- next field is not supported first pass wanEntDialPhoneNumMax OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { wanTblEnt 5 } -- next field is not supported first pass wanEntDialPhoneTbl OBJECT-TYPE SYNTAX SEQUENCE OF WanEntDialPhoneEnt ACCESS not-accessible STATUS mandatory ::= { wanTblEnt 6 } -- next field is not supported first pass wanEntDialPhoneEnt OBJECT-TYPE SYNTAX WanEntDialPhoneEnt ACCESS not-accessible STATUS mandatory ::= { wanEntDialPhoneTbl 1 } -- next field is not supported first pass WanEntDialPhoneEnt ::= SEQUENCE { wanEntDialPhoneEntID INTEGER, wanEntDialPhoneEntPhone DisplayString } -- next field is not supported first pass wanEntDialPhoneEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { wanEntDialPhoneEnt 1 } -- next field is not supported first pass wanEntDialPhoneEntPhone OBJECT-TYPE SYNTAX DisplayString (SIZE (0..25)) -- a dialable string passed to modem ACCESS read-write STATUS mandatory ::= { wanEntDialPhoneEnt 2 } wanEntGroups OBJECT-TYPE SYNTAX OCTET STRING -- 256 bit map of the groups which are enabled ACCESS read-write STATUS mandatory ::= { wanTblEnt 7 } -- next field is not supported first pass wanEntModemType OBJECT-TYPE SYNTAX INTEGER { dedicated(1), dialUp(2) } ACCESS read-write STATUS mandatory ::= { wanTblEnt 8 } wanEntNullClock OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory ::= { wanTblEnt 9 } wanEntPathcostWeighted OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory ::= { wanTblEnt 10 } wanEntErrorRateCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanTblEnt 11 } wanEntErrorRateHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanTblEnt 12 } wanEntErrorRateAvg OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanTblEnt 13 } wanEntLinkDownCur OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanTblEnt 14 } wanEntLinkDownHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanTblEnt 15 } wanEntLinkDownTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 16 } wanEntLinkDownCount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 17 } wanEntCableType OBJECT-TYPE SYNTAX INTEGER { cable422(1), cable423(2), cableV35(3), unknown(4) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 18 } wanEntCtsCur OBJECT-TYPE SYNTAX INTEGER { no(1), observed(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 19 } wanEntRtsCur OBJECT-TYPE SYNTAX INTEGER { no(1), asserted(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 20 } wanEntDcdCur OBJECT-TYPE SYNTAX INTEGER { no(1), observed(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 21 } wanEntDsrCur OBJECT-TYPE SYNTAX INTEGER { no(1), observed(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 22 } wanEntDtrCur OBJECT-TYPE SYNTAX INTEGER { no(1), asserted(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 23 } wanEntRingCur OBJECT-TYPE SYNTAX INTEGER { no(1), observed(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 24 } wanEntCtsChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 25 } wanEntRtsChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 26 } wanEntDcdChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 27 } wanEntDsrChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 28 } wanEntDtrChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 29 } wanEntRingChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 30 } wanEntCompNum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { wanTblEnt 31 } wanEntCompressionTbl OBJECT-TYPE SYNTAX SEQUENCE OF WanEntCompEnt ACCESS not-accessible STATUS mandatory ::= { wanTblEnt 32 } wanEntCompEnt OBJECT-TYPE SYNTAX WanEntCompEnt ACCESS not-accessible STATUS mandatory ::= { wanEntCompressionTbl 1 } WanEntCompEnt ::= SEQUENCE { wanEntCompEntID INTEGER, wanEntCompEntDescription DisplayString, wanEntCompEntCurrent Gauge, wanEntCompEntHigh Gauge, wanEntCompEntAverage Gauge } wanEntCompEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { wanEntCompEnt 1 } wanEntCompEntDescription OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory ::= { wanEntCompEnt 2 } wanEntCompEntCurrent OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanEntCompEnt 3 } wanEntCompEntHigh OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanEntCompEnt 4 } wanEntCompEntAverage OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory ::= { wanEntCompEnt 5 } wanEntCompressionStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory ::= { wanTblEnt 33 } wanVitalinkCompatibility OBJECT-TYPE SYNTAX INTEGER { auto(1), enabled(2) } ACCESS read-write STATUS mandatory ::= { wan 4 } -- the lan group lan OBJECT IDENTIFIER ::= { bridge 7 } lanNum OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lan 1 } lanTbl OBJECT-TYPE SYNTAX SEQUENCE OF LanTblEnt ACCESS not-accessible STATUS mandatory ::= { lan 2 } lanTblEnt OBJECT-TYPE SYNTAX LanTblEnt ACCESS not-accessible STATUS mandatory ::= { lanTbl 1 } LanTblEnt ::= SEQUENCE { lanEntID INTEGER, lanEntShutdownThreshold INTEGER, lanEntFramingError Counter, lanEntLostPacketsError Counter, lanEntMemoryError Counter, lanEntOverflowError Counter, lanEntPacketInTooLongError Counter, lanEntCarrierLossError Counter, lanEntHeartbeatFailureError Counter, lanEntLateCollisionError Counter, lanEntPacketOutTooLongError Counter, lanEntRetryExceedError Counter } lanEntID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { lanTblEnt 1 } lanEntShutdownThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory ::= { lanTblEnt 2 } lanEntFramingError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 3 } lanEntLostPacketsError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 4 } lanEntMemoryError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 5 } lanEntOverflowError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 6 } lanEntPacketInTooLongError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 7 } lanEntCarrierLossError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 8 } lanEntHeartbeatFailureError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 9 } lanEntLateCollisionError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 10 } lanEntPacketOutTooLongError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 11 } lanEntRetryExceedError OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory ::= { lanTblEnt 12 } END